3.2.8
Adjustment of Document Stop Position in the Single Feed Mode
Requirement
The document should be 0 to 1 mm in the direction of b from the end face of the
Original Width Scale.
1. Set "U-4" (Lightweight Original) of User's Choice to "1." (Make the adjustment
in the Lightweight Original mode.)
NOTE: Metric areas only
2. Slide the Document Positioning Plate towards the rear and secure it with tape.
3. Affix a piece of tape to each of the Magnet Catch Plates.
4. Place a document into the Manual Feed Port, and press the Stop key
immediately.
5. Open the ADF gently and check whether the document is aligned with the edge
of the Original Glass.
6. Set the service choice mode "c-37".
7. Referring to page D-17, adjust the document stop position.
Rev. 1.0/05.99
NOTE
a
b
D-15
AFR-12/AF-5