3.2.3
Adjustment of the Single Feed Tray
Requirement
The document Feed Table should be positioned within +/- 1 mm from the edge of
the Document Positioning Plate.
1. Slide the Document Positioning Plate towards the rear and secure it with tape.
2. Affix a piece of tape to each of the Magnet Catch Plates.
1. Place a document on the Document Feed Table and select 1-sided mode.
2. Press the Start key, then press the Stop key immediately.
3. Open the ADF gently and remove the tape from the Document Positioning
Plate, taking care not to allow the document to move.
4. Check whether the document is aligned with the edge of the Document
Positioning Plate.
5. If the document is off in direction "a", move the Single Feed Tray towards you.
If the document is off in direction "b", move the Single Feed Tray towards the
rear.
AFR-12/AF-5
a
b