3.1.6
Removal of the Turnover/Exit Assy (AFR-12)
Remove the Transport Belt, Maintenance Cover and unplug the connectors
from PWB-A as shown in the figure.
Open the Turnover/Exit Cover and remove the screw.
Remove the Cover and grounding wire (black).
Remove five screws, open the Turnover/Exit Cover and lift out the Turnover/
Exit Unit Assy.
When reinstalling the Turnover/Exit Unit Assy, make sure that the Turnover/Exit
Cover is open.
AFR-12/AF-5
NOTE
D-6
Rev. 1.0/05.99