Konica Minolta AFR-12 General, Mechanical/Electrical page 39

Table of Contents

Advertisement

2.1.4
Sensor Adjustment Check
1. Set the SW1-6 to ON with the Main Switch set to OFF.
2. Turn the Main Switch ON, select the sensor adjustment mode as shown in the
following table, then open and close the ADF to confirm the selection.
Test Mode
Sensor Adjustment
3. Turn the PSW1 ON to start the test.
An error will occur if adjustment is carried out with the take-up/turnover cover open.
So make sure that the cover is closed before starting adjustment.
– Registration Sensor Adjustment –
– Exit Sensor Adjustment –
2.1.5
Rev. 1.0/05.99
1
2
3
ON
OFF
OFF
NOTE
LED1
LED2
LED3
LED4
: Not lit
: Lit up
S-9
SW1
4
5
ON
OFF
Sensor Status
Initialized
Upper-limit error
Lower-limit error
Adjustment complete
Sensor Status
Initialized
Upper-limit error
Lower-limit error
Adjustment complete
AFR-12/AF-5