Konica Minolta AFR-12 General, Mechanical/Electrical page 34

Table of Contents

Advertisement

2.1.2
Unit Check
1. Set SW1-6 to ON with the Main Switch set to OFF.
2. Turn the Main Switch ON, select the desired mode from the following table, then
open and close the ADF to confirm the selection.
Test Mode
Take-Up Motor Check
Transport Motor Check
Exit Motor Check
Solenoid Check
3. Turn PSW1 ON to start the test.
–Take-Up Motor Check–
AFR-12/AF-5
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
LED
1
2
3
4
: For monotoring
S-4
SW1
3
4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Number of
Times PSW1
5
is Turned ON
0
1
Forward rotation
2
3
Backward rotation
: Not lit
: Lit up
Rev. 1.0/05.99
5
6
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Operation
Stop
Stop

Advertisement

Table of Contents
loading

This manual is also suitable for:

Af-5

Table of Contents