Sca File Example - ADTRAN Total Access 1240 Installation And Maintenance Practice

Adtran modem installation and maintenance practice
Table of Contents

Advertisement

Total Access 1240 Installation and Maintenance Practice
Table B-5. LocSTULineProvisioning (Continued)
Column
Option
17
Performance Primitive
Notifications
18
SHDSL ES 15 Minute Alarm
Threshold
19
SHDSL SES 15 Minute Alarm
Threshold
1A
SHDSL UAS 15 Minute Alarm
Threshold
1B
SHDSL CVC 15 Minute Alarm
Threshold
1C
SHDSL LOSWS 15 Minute
Alarm Threshold
1D
Line Rate Control
1E
SHDSL OS 15 Minute Alarm
Threshold
1F
Outage Auto-Retrain
20 - 27
Reserved Options for future use

SCA FILE EXAMPLE

Figure B-1
provides an example of an SCA file.
B-6
Values
bit 7 = segment anomaly
bit 6 = CRC anomaly
bit 5 = segment defect
bit 4 = loss of sync word defect
bit 3 = SNR margin defect
bit 2 = loop attenuation defect
bit 1 = loss of sync word failure
bit 0 = tip/ring reversal
0 = Disabled
1 to 900 = threshold in seconds
0 = Disabled
1 to 900 = threshold in seconds
0 = Disabled
1 to 900 = threshold in seconds
0 = Disabled
1 to 65535 = threshold in seconds
0 = Disabled
1 to 900 = threshold in seconds
0 = STU-C
1 = STU-R
0 = Disabled
1 to 900 = threshold in seconds
0 = Disabled
1 = Enabled
61179605L5-5B

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF