Card Provisioning Menu

The Card Provisioning menu (see
circuit board card. The default value for the Card Service State is Out of Service-Maintenance.
Changes to this service state are reflected on all 24 ports.
The Card Provisioning menu options are shown in
Option
Description
1
Service State
2
Restore Factory Defaults
61179605L5-5B
Figure
5-49) is used to set the service state of the main
Total Access 1240
Card Provisioning
1.
Service State
2.
Restore Factory Defaults
Selection:
'?' - System Help

Figure 5-49. Card Provisioning Menu

Table 5-50. Card Provisioning Menu Options

Function
This option is used to select the card service state. The
available service states are as follows:
This option displays the
Screen"
Section 5, User Interface - Menu Descriptions
= OOS-Maintenance
Table
5-50.
• In Service – The SHDSL services are available, if
installed, and Link Down and Threshold alarms are
reported.
• Out of Service-Unassigned – No SHDSL services are
available. No Link Down and Threshold alarms are
reported.
• Out of Service-Maintenance – SHDSL services are
available. No Link Down and Threshold alarms are
reported.
on page 5-70.