4.6
Electrical connection of clamping
device
4.6.1

EPS 708

Connect the trigger electronics by way of the con-
necting cable 1 684 463 698 (scope of delivery of
EPS 708) to connection X23 in the test area of the
EPS 708.
Fig. 35:
Connection of trigger electronics
Robert Bosch GmbH
Initial startup | CRI/CRIN 848H | 71
4.6.2
EPS 815
1. Join connecting cable (Fig. 36, item 1) 1 684 462 298
to X4 terminal of the control electronics.
2. Connect voltage supply cable (Fig. 36, item 2)
1 684 463 504 to X2 terminal.
3. Connect voltage supply cable (Fig. 36, item 3)
1 684 463 503 to X1 terminal.
3
2
1
Fig. 36:
Control electronics connection
1 RS 232 connecting cable
2 Voltage supply cable (-) 1 684 463 504
3 Voltage supply cable (+) 1 684 463 503