Application Example Of Safety Functions - YASKAWA Σ-V Series User Manual

Ac servo drives; linear motor command option attachable type
Hide thumbs Also See for Σ-V Series:
Table of Contents

Advertisement

4 Operation

4.7.3 Application Example of Safety Functions

4.7.3

Application Example of Safety Functions

An example of using safety functions is shown below.
(1) Connection Example
In the following example, a safety unit is used and the HWBB function operates when the guard opens.
When a guard opens, both of signals, the /HWBB1 and the /HWBB2, turn OFF, and the EDM1 signal is ON.
Since the feedback circuit is ON when the guard closes, the safety unit is reset, and the /HWBB1 and the /
HWBB2 signals turn ON, and the operation becomes possible.
Note: Connect the EDM1 as the direction of current flows from EMD1+ to EMD1-, because the EMD1 has polarity with a
transistor output.
(2) Failure Detection Method
In case of a failure such as the /HWBB1 or the /HWBB2 signal remains ON, the safety unit is not reset
because the EDM1 signal keeps OFF. Therefore starting is impossible, then the failure is detected.
An error in the external device, disconnection or short-circuiting of the external wiring, or a failure in the
SERVOPACK must be considered. Find the cause and correct the problem.
4-48
Close
Limit switch
Guard
24 V
Power
supply
Open
Fuse
A1
T11 T12 T21
Input
Power
supply
Reset/feedback
input
input
A2
T31 T32 T33
0 V
Safety unit
G9SX-BC202
manufactured
by OMRON Corp.
T22
Output
SERVOPACK
S24 S14
CN8
/HWBB1+
4
/HWBB1−
3
/HWBB2+
6
/HWBB2−
5
EDM1+
8
7
EDM1−

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents