Sequence Output Circuits - YASKAWA Σ-V Series User Manual

Ac servo drives; linear motor command option attachable type
Hide thumbs Also See for Σ-V Series:
Table of Contents

Advertisement

3 Wiring and Connection

3.4.2 Sequence Output Circuits

3.4.2 Sequence Output Circuits

The following diagrams show examples of how output circuits can be connected the SERVOPACK.
(1) Photocoupler Output Circuit
Photocoupler output circuits are used for servo alarm (ALM), servo ready (/S-RDY), and other sequence out-
put signal circuits. Connect a photocoupler output circuit through a relay or line receiver circuit.
Note: The maximum allowable voltage and current capacities for photocoupler output circuits are as follows.
• Voltage: 30 VDC
• Current: 5 to 50 mA DC
(2) Line Driver Output Circuit
CN1 connector terminals, 17-18 (phase-A signal), 19-20 (phase-B signal), and 21-22 (phase-C signal) are
explained below.
Linear scale serial data converted to two-phase (phases A and B) pulse output signals (PAO, /PAO, PBO, /
PBO) and origin pulse signals (PCO, /PCO) are output via line-driver output circuits. Connect the line-driver
output circuit through a line receiver circuit at the host controller.
3-26
Incorrect wiring or incorrect voltage application to the output circuit may cause short-cir-
cuit.
The above failures will prevent the holding brake from working, which may damage the
machine or cause an accident resulting in death or injury.
Relay Circuit Example
SERVOPACK
5 to 24 VDC
0 V
Applicable line driver
SN75174 manufactured
by Texas Instruments or
the equivalent
SERVOPACK
Relay
Line Receiver Circuit Example
SERVOPACK
Host Controller
Applicable line receiver
SN75ALS175 or the
equivalent
220 to
Ω
470
Line Receiver Circuit Example
5 to 12 VDC

Hide quick links:

Advertisement

Table of Contents
loading