1.3

SERVOPACK Ratings and Specifications

This section describes the ratings and specifications of SERVOPACKs.

1.3.1 Ratings

Ratings of SERVOPACKs are as shown below.
(1) SGDV Single-phase 100-V Ratings
SGDV
(Single-phase, 100 V)
Continuous Output Current
[Arms]
Max. Output Current [Arms]
Regenerative Resistor
Main Circuit Power Supply
Control Power
Overvoltage Category
Refer to 3.7 Regenerative Resistors Connections for details.
(2) SGDV Single-phase 200-V Ratings
SGDV (Single-phase, 200 V)
Continuous Output Current
[Arms]
Max. Output Current [Arms]
Regenerative Resistor
Main Circuit Power Supply
Control Power
Overvoltage Category
∗1. The official model number is SGDV-120AE5A008000.
∗2. Refer to 3.7 Regenerative Resistors Connections for details.
(3) SGDV Three-phase 200-V Ratings
SGDV (Three-phase, 200 V)
Continuous Output Current
[Arms]
Max. Output Current [Arms]
Regenerative Resistor
Main Circuit Power Supply
Control Power
Overvoltage Category
Refer to 3.7 Regenerative Resistors Connections for details.
R70
R90
0.66
0.91
2.1
2.9
*
None/External
Single-phase, 100 to 115 VAC
Single-phase, 100 to 115 VAC
III
11.6
28
*2
Built-in/External
Single-phase, 220 to 230 VAC
Single-phase, 220 to 230 VAC
III
R70
R90
1R6
0.66
0.91
1.6
2.1
2.9
5.8
*
None/External
Three-phase, 200 to 230 VAC
Single-phase, 200 to 230 VAC
III

1.3 SERVOPACK Ratings and Specifications

2R1
2R8
2.1
2.8
6.5
9.3
+10%
, 50/60 Hz
−15%
+10%
, 50/60 Hz
−15%
*1
120
+10%
, 50/60 Hz
−15%
+10%
, 50/60 Hz
−15%
2R8
3R8
5R5
7R6
120
2.8
3.8
5.5
7.6
11.6
9.3
11.0
16.9
17
28
Built-in/External
+10%
, 50/60 Hz
−15%
+10%
, 50/60 Hz
−15%
180
200
330
550
18.5
19.6
32.9
54.7
42
56
84
130
Exter
nal
1