Appendix

12.3 Relays and Memory Areas for FP0R

Relays [bits]
Memory
Type
size
External input
1760
1)
relays
External
1760
1)
output relays
Internal relays
4096
2)
2)
Link relays
2048
2)
Timer relays
1024
3)
Counter relays
1024
2) 3)
Special
224
internal relays
Memory area [words]
Memory
Type
size
External input
110
1)
relays
External output
110
1)
relays
2)
Internal relays
256
Link relays
128
C10,
C14,
12315
C16
Data
2)
registers
C32,
T32,
32763
F32
2)
Link registers
256
Timer/counter set
1024
2)
value area
Timer/counter
1024
2)
elapsed value area
Special data
440
registers
256
Available address area
FP
IEC
%IX0.0–
X0–X109F
%IX109.15
%QX0.0–
Y0–Y109F
%QX109.15
%MX0.0.0–
R0–R255F
%MX0.255.15
%MX7.0.0–
L0–L127F
%MX7.127.15
%MX1.0–
T0–T1007/
%MX1.1007/
C1008-C1023
%MX2.1008–
%MX2.1023
%MX2.1008–
C1008–C1023/
%MX2.1023/
T0–T1007
%MX1.0–
%MX1.1007
%MX0.900.0–
R9000–R913F
%MX0.913.15
Available address area
FP
%IW0–
WX0–WX109
%IW109
%QW0–
WY0–WY109
%QW109
%MW0.0–
WR0–WR255
%MW0.255
%MW7.0–
WL0–WL127
%MW7.127
%MW5.0–
DT0–DT12312
%MW5.12312
%MW5.0–
DT0–DT32762
%MW5.32762
%MW8.0–
LD0–LD255
%MW8.255
%MW3.0–
SV0–SV1023
%MW3.1023
%MW4.0–
EV0–EV1023
%MW4.1023
DT90000–
%MW5.90000–
DT90439
%MW5.90439
Turn on or off based on external input.
Turn on or off external outputs based on the
operation result.
Used internally by the PLC program to store bit
information.
Shared by multiple PLCs connected using PLC
link.
Turn on when the value set with a TM instruction
for the timer with the same number has reached 0.
Turn on when the value set with a CT instruction
for the counter with the same number has reached
0.
Turn on or off based on specific conditions. Used
internally as a flag.
IEC
Code for specifying 16 external input points
as one word (16 bits) of data.
Code for specifying 16 external output points
as one word (16 bits) of data.
Code for specifying 16 internal relays as one
word (16 bits) of data.
Code for specifying 16 link relays as one
word (16 bits) of data.
Data memory used in a program. Data is
handled in 16-bit units (one word).
Data memory shared by multiple PLCs
connected using PLC link. Data is handled in
16-bit units (one word).
Data memory for storing the set values of
timers or counters. The values are stored by
timer/counter number.
Data memory for storing the elapsed values
during operation of timers or counters. The
values are stored by timer/counter number.
Data memory for storing settings and error
codes.
Function
Function