Panasonic FP0R User Manual page 145

Hide thumbs Also See for FP0R:
Table of Contents

Advertisement

Communication
Communication format settings for Micro-Imagechecker A100/A200
To set the communication mode and transmission format settings for the Micro-Imagechecker,
select "5: Communication" under "5: ENVIRONMENT" on the main menu, and set the
following items.
No.
Name
51
Communication mode
52
RS232C
53
Serial Output
NOTE
If "Del" is specified for the invalid processing parameter, zero suppression
processing will be carried out on the output data, and the output format will
be changed. Always make sure "Repl. 0" is specified.
When outputting data to an external device, numerical calculation is
required, so "Out" should be specified for the "Numerical calculation"
parameter.
With the above settings, the following data will be output from the Micro-Imagechecker:
1 0 1 2 3 4 5
C R
2
3
4
1
Terminator (end code)
2
Results of numerical calculation No. 1
144
Set value
Normal Mode
Baud rate:
Length:
Stop bit:
Parity:
Flow Control:
Output:
Invalid Digit:
Read End:
Process End:
Numerical Calculation:
Judgment:
1
3
Judgment output No. 2 0=NG
4
Judgment output No. 1 1=OK
9600bit/s
8
1
Odd
None
5 Column
Repl. 0
None
None
Output
Output