Pulse/direction
Forward FALSE
+
FALSE
a
Control is carried out using one pulse output to specify the
speed and another to specify the direction of rotation with
TRUE/FALSE signals. In this mode, forward rotation is
carried out when the rotation direction signal is FALSE.
Forward TRUE
+
TRUE
a
Control is carried out using one pulse output to specify the
speed and another to specify the direction of rotation with
TRUE/FALSE signals. In this mode, forward rotation is
carried out when the rotation direction signal is TRUE.
Relative value control
The number of pulses set with the target value is output. Positive values result in a positive
rotation, negative values in a negative rotation.
EXAMPLE
With a current position of 5000 and a target value of +1000, 1000 pulses are output
from CW to reach the new position at 6000.
-
TRUE
b
-
FALSE
b
High-Speed Counter and Pulse Output
Pulse output: Y0 (Y2)
1
Direction output: Y1 (Y3)
2
Incremental counting
a
Decremental counting
b