High-Speed Counter and Pulse Output
Resetting the elapsed value (software reset) of the high-speed counter to 0
1
0
Y*
2
Y*
Pulse output
1
Elapsed value
2
Bit 0 of pulse output control code (software reset)
When bit 0 of the control code is set to TRUE, a software reset is performed and the elapsed
value is set to 0. The elapsed value keeps the value 0 until bit 0 is reset to FALSE.
Clearing high-speed counter and position control instructions
To cancel execution of a pulse output instruction, set bit 2 of the data register storing the
pulse output control code (sys_wHscOrPulseControlCode) to TRUE. The pulse output control
flag will then change to FALSE. To reenable execution of the instruction, reset bit 2 to FALSE.
204
0
t
1