Do NOT install the CPU as shown below.
1
1
Upside-down
2
Upside-down
3
Input and output connectors face down
4
Input and output connectors on top
5
Horizontal installation of the unit
Do not install the unit above devices which generate heat such as heaters,
transformers or large scale resistors.
Installation space
Leave at least 50mm of space between the wiring ducts of the unit and other devices
to allow heat radiation and unit replacement.
Maintain a minimum of 100mm between devices to avoid adverse affects from noise
and heat when installing a device or panel door to the front of the unit.
100mm
Keep the first 100 mm from the unit's front surface clear of objects to allow wiring and
2
3
≥ 50mm
≥ 50mm
4
1
PLC
2
Other device
Panel door
3
Installation and Wiring
5
69