1
2. Heating capacity performance data
Power
Model
Source
220V-230V-240V
S-100PU2E5B×2
50Hz 1phase
(U-200PZH2E8)
(380V-400V-415V
50Hz 3phase)
220V-230V-240V
S-71PU2E5B×3
50Hz 1phase
(U-200PZH2E8)
(380V-400V-415V
50Hz 3phase)
220V-230V-240V
S-50PU2E5B×4
50Hz 1phase
(U-200PZH2E8)
(380V-400V-415V
50Hz 3phase)
220V-230V-240V
S-125PU2E5B×2
50Hz 1phase
(U-250PZH2E8)
(380V-400V-415V
50Hz 3phase)
220V-230V-240V
S-60PU2E5B×4
50Hz 1phase
(U-250PZH2E8)
(380V-400V-415V
50Hz 3phase)
Ambient
Return
-21°C
Air
DB
TC
IPT
16
16.0
6.37
20
14.8
6.76
24
13.5
7.16
16
16.0
6.37
20
14.8
6.76
24
13.5
7.16
16
16.0
6.37
20
14.8
6.76
24
13.5
7.16
16
20.2
8.14
20
18.6
8.65
24
17.0
9.15
16
20.2
8.14
20
18.6
8.65
24
17.0
9.15
Outdoor air intake temp(°C W.B.)
-8°C
6°C
TC
IPT
TC
IPT
21.9
6.89
26.3
7.51
20.6
7.29
25.0
7.90
19.4
7.68
23.8
8.30
21.9
6.89
26.3
7.51
20.6
7.29
25.0
7.90
19.4
7.68
23.8
8.30
21.9
6.89
26.3
7.51
20.6
7.29
25.0
7.90
19.4
7.68
23.8
8.30
27.5
8.81
33.1
9.60
26.0
9.32
31.5
10.1
24.4
9.82
29.9
10.6
27.5
8.81
33.1
9.60
26.0
9.32
31.5
10.1
24.4
9.82
29.9
10.6
1-13-3
TC
:Heating Capacity
IPT :Heating Power Consumption
unit : kW
8°C
15°C
TC
IPT
TC
IPT
21.7
5.06
26.5
5.12
20.5
5.45
25.3
5.52
19.2
5.85
24.0
5.91
21.7
5.06
26.5
5.12
20.5
5.45
25.3
5.52
19.2
5.85
24.0
5.91
21.7
5.06
26.5
5.12
20.5
5.45
25.3
5.52
19.2
5.85
24.0
5.91
27.4
6.47
33.4
6.55
25.8
6.97
31.9
7.05
24.2
7.48
30.3
7.56
27.4
6.47
33.4
6.55
25.8
6.97
31.9
7.05
24.2
7.48
30.3
7.56