Adding Alarm Contacts To Cameras; Viewing Salvo Callups To Cameras - American Dynamics MegaPower 3200 Administrator's Manual

Megapower cpu
Hide thumbs Also See for MegaPower 3200:
Table of Contents

Advertisement

Note: By default, pseudo numbers in this
dialog box match the physical camera
numbers. In all other screens and dialogs,
references to camera numbers are actually
references to the defined pseudo numbers.
• Title 1 – You can create a two-line title for
each camera that will display on the monitor
when the camera is called. Title 1 is the upper
line of the title and can be up to eight
characters or digits in length with the pseudo
number appended to the title. Titles over eight
characters are truncated.
• Title 2 – Title 2 allows you to create the lower
line of a two-line camera title. Title 2 can be up
to eight characters or digits in length.
• Video Loss Detection – Provides video loss
detection alarming. You can set video loss
detection for the following conditions:
− Off – Video loss detection not enabled
− Sync – To detect a reduction or loss of the
video signal level
− Low – To detect low picture content
− Medium – To detect medium picture
content
− High – To detect high picture content
• Remote Site – Identifies the remote site that
provides the video trunk inputs to the selected
local camera.
• Remote Output – Identifies the monitor output
from the remote site that is connected to the
selected local camera input.
• Pan/Tilt – Identifies whether the selected
camera has pan/tilt capability. This field is not
downloaded to the system, but is for
informational purpose only.
• Alarm Number – Not currently implemented.
• Location – Identifies the location of the
camera (up to 16 characters). Location is not
downloaded to the system, but is used for
database reports and easy identification.
3. Click OK to display the new definition or Cancel
to close the dialog box without displaying the
definition.
Note: Remember to save or transfer your
changes before closing EASY CPU.
MEGAPOWER CPU
ADMINISTRATOR'S GUIDE
Editing Camera Definitions
Once a camera is defined, you can edit the definition
by highlighting the information in the desired field and
entering new information.
For example, to position Title1 on the monitor, click
on the Center Title1 field, and choose the desired
title position from the dropdown menu that appears:
Left, Center, Right, or None (no title will be
displayed).

Adding Alarm Contacts to Cameras

The Alarm Contacts tab section allows you to specify
the alarm contacts associated with the highlighted
camera.
The Alarm Contacts tab contains the following fields:
Figure 79. Cameras Alarm Contacts tab screen
• Contact No. – Number of the alarm contact
associated with the camera
• Preset Pattern – Pattern or preset number
associated with the camera
• Link – Choose either No, Yes, Wired, No Group
Ack, Yes Group Ack, or Wired Group Ack
• Aux – Choose either Don't Care, Aux 1 On, Aux 1
Off, Aux 2 On, Aux 2 Off, Aux 3 On, Aux 3 Off, or
Aux 4 On
• Dwell – Enter the dwell time in seconds
• Alarm Message – Enter the alarm message
number to be associated with the camera.
Note: Alarm messages are first created in the
Alarms – Alarm Messages screen.
• Email Message – Enter the email message
number to be associated with the camera.
Note: Email messages are first created in the
Alarms – Email Messages screen.

Viewing Salvo Callups to Cameras

The Salvo Callups tab on the Definitions – Cameras
screen allows you to view Salvos that are associated
with selected cameras.