Schedule Setup
Normal — Record images at normal image quality. This
setting provides a balance between compression and storage
space requirements.
Extended Record — Record images at the highest level of
compression. This setting requires the lowest amount of
storage space.
Pre-Alarm Sensitivity — This setting lets you control how
Intellex responds to small, subtle changes between images. Select
the sensitivity to use when storing pre-alarm images. The default is
Normal.
High — At this setting, Intellex records the smaller changes
between images, improving the perceived picture quality. As a
result, this setting requires more storage space.
Normal — At this setting, Intellex ignores the smaller, more
subtle changes between images.
Live Filter — Use this option to select the live filter to use during
this segment. When the live filter is activated, the unit switches to
alarm mode. The default is None.
NOTE: Before you can configure a live filter, you must record at
least one image from the camera. Until an image is
recorded, the filter options are disabled.
1.
Click down arrow. A list of filters appears.
2.
Click the desired filter. Select None to disable any previously
configured filters.
3.
Click Setup
to configure the filter (see
Configuration
on page 68).
Pre-Alarm Duration — The unit continuously saves pre-alarm
images for each camera, up to the pre-alarm duration. When an
event occurs, the unit records these images to the image database.
The default is 15 Seconds.
1.
Click down arrow. A list of options appears.
2.
Click the desired pre-alarm duration.
Setup — Select a filter for this segment; then click Setup to
configure it (see
Live Filter Configuration
Live Filter
on page 68).