146
Alarm Operations
Intellex
3.
The unit adds the alarm camera to the alarm group and
records its images more often than nonalarm cameras (see
Alarm Groups
on page 147).
4.
The unit lights the Alarms indicator as soon as the alarm is
cleared.
5.
The unit flags the video segment in the image database with
the name Gen. Alarm.
6.
If the Pre-Alarm Duration option is selected, the unit saves
the pre-alarm images to the image database (see
Schedule Setup
on page 50).
7.
If the Alarm Message Display option is selected (see
Setup
on page 78):
a.
If the camera is not currently displayed or is displayed in
the camera sequencing window, the unit switches the
live display monitor to the 4x4 format and overrides the
display settings for the duration of the alarm (see
Setup
on page 82).
b. The unit displays ALARM over the camera image.
c.
If the Latch Messages option is selected (see
Setup
on page 78), the unit enables the Clear Latched
button on the Utility Options screen (see
page 105).
d. The unit suspends camera sequencing on the live display
monitor.
8.
If the Unit Alarm Out option is selected, the unit energizes
the alarm output associated with camera 16 (see
on page 78).
The unit remains in the alarm state until ALL of the following
occur:
a.
All alarms, including mechanical, are released.
b. The Duration time elapses (see
Once the unit exits the alarm state, it returns to the previous display
mode, record mode and quality settings.
®
LT Digital Video Management System
Alarms Setup
Custom
Alarms
Display
Alarms
Utility Options
on
Alarms Setup
on page 78).