Header and Pipe Shield Installation
The header and pipe shield must be installed as shown below.
NOTE: The header and pipe shields may be installed after the fireplace is in place and vent attached (this
allows for the fireplace to fit into the framing underneath the header and for the vent to be installed more
easily).
1
Remove the pipe shield from its shipping location by removing the (4) - ¼" screws attaching it to
the back of the fireplace (Keep the screws for reinstallation).
2
At each of the perforations, bend the sides of the pipe shield backwards 90° as shown below.
NOTE: The bottom flanges should be facing outward
Bend at perforations
© Travis Industries
Installation
(for qualified installers only)
Remove shield
11/9/20 - 1478
Remove the (4) screws
securing the shield
Tabs face out.
PB 72 GSB2/GSR2 Aust.
15