Electrical Connection - Lopi Pro Builder 72 Linear GSB2 Installation Manual

Table of Contents

Advertisement

Electrical Connection

The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must be a min. 14 gauge, and supply 240 Volts, 60 Hz, and 5.7 Amps.
Route the electrical connection through the junction box cover plate and attach to the hookup wires
pictured below.
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation.
Do not connect 110-240 VAC to the gas control valve or wiring system of this fireplace.
Left Side Electrical Junction Box Location
b
1
© Travis Industries
Installation
a
2
(for qualified installers only)
a
10-5/8" (270mm)
3
11/9/20 - 1478
b
2-3/8" (61mm)
4
PB 72 GSB2/GSR2 Aust.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro builder 72 linear gsr2

Table of Contents