Using Oval Pipe To Get Past An Obstruction - Lopi Pro Builder 72 Linear GSB2 Installation Manual

Table of Contents

Advertisement

4
Insert a starter collar into each of the (6) holes that were uncovered in the previous step and bend the
tabs to secure the starter collar to the fireplace.. Seal the joints with silicone caulk or aluminum (U.L.
181A-P) tape
5
Install the fireplace into the framed chase. See section "Installation" in the manual.
NOTE: With the use of this kit, the clearance to combustible material may be reduced. Combustible
material may be installed to the top of the fireplace box. Non-combustible is still required on all
front surfaces of the fireplace box.
See instructions included with the CoolSmart TV kit for further details.

Using oval pipe to get past an obstruction

If a situation arises that obstructs the
CoolSmart flex vent runs (such as
getting past a minimum sideways
vent) you may transition the 5" flex
vent to a ridged nominal 6" oval pipe
to get past the obstruction. Transition
back to the 5" round flex and continue
to the manifold.
The adapters and ridged pipe should
be factory ovalized, not field ovalized.
NOTE: All clearances to combustibles
must be maintained.
© Travis Industries
Installation
(for qualified installers only)
5"
5"
Starter Collar
Use silicone to seal the
starter collar to the top
of the fireplace.
Bend the tabs on the
bottom of the starter
collar up to lock it in
place.
7-3/4"
3"
7-3/4"
5"
3"
11/9/20 - 1478
67
5" Flex
to CoolSmart
Manifold
5" round to 6"
oval adapter
6" oval
pipe
5" round to 6"
oval adapter
5" Flex
to fireplace
PB 72 GSB2/GSR2 Aust.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro builder 72 linear gsr2

Table of Contents