Optional Wall Switch or Thermostat Installation (GSB2 only)

Do not connect 240 VAC to the gas control valve or wiring system of this fireplace. The switch and
wiring must be installed by a qualified installer.
This fireplace includes an optional wall switch (with wire) to
operate the fireplace burner without accessing the internal
on/off switch. A thermostat may be used instead.
Route the wire from inside the fireplace, through the grommet
on either side of the fireplace (see illustration to the right) to
the switch. The wall switch (or thermostat) may bypass the
fireplace on/off switch or be installed in parallel or series
configuration (see below).
Caution:
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Warning:
Make sure all wiring is secure and does not
contact hot or moving components.
Parallel Connection
Thermostat / External
Switch ON
Thermostat / External
Switch OFF
To wire the heater in parallel, follow the directions below:
a
On / Off Switch
c
© Travis Industries
Installation
On / Off Switch
On / Off Switch
ON
OFF
Heater is ON
Heater is ON
Heater is ON
Heater is OFF
b
Thermostat
(or External Switch) Wires
(for qualified installers only)
OPTIONAL WALL SWITCH
(included with fireplace)
Place "WARNING"
label on switch cover.
Series Connection
Thermostat /
External Switch ON
Thermostat /
External Switch OFF
To wire the heater in series, follow the directions below:
a
On / Off Switch
11/9/20 - 1478
On / Off Switch
ON
Heater is ON
Heater is OFF
b
(or External Switch) Wires
c
PB 72 GSB2/GSR2 Aust.
On / Off Switch
OFF
Heater is OFF
Heater is OFF
Thermostat