Facing Thicker than 1-1/2" (38mm)

If using thick facing, make sure to leave the thick facing guide in place.
Make sure to leave the screen assembly in the stock (fully in) position.
You may leave the screen assembly in place while installing thick facing. You may wish to
protect it with plastic (or other suitable material) to repel debris.
When using thick facing, make sure to install the facing above, below, and to the sides of the thick facing
guide. Do not allow any facing material to overlap the thick facing guide (this would prevent removal of
the screen assembly).
Screen Assembly Mount
Screen Assembly

THICK FACING GUIDE SIZE

Tile Stop to
Base of
Fireplace
5-1/4" (134mm)
© Travis Industries
Installation
(for qualified installers only)
Fireplace
Thick Facing Guide
THICK FACING GUIDE LOCATION (PB LINEAR)
Extends 5/8" (16mm) above the tile stop
Extends 5/8" (16mm) to the sides of the tile stop
Extends 3/8" (9.5mm) below the tile stop
Tile Stop Width
4-7/8"(124mm)
Thick Facing
(brick, rock, etc.)
Tile Sto
b
a
11/9/20 - 1478
Framing
Backerboard
75"
PB72
Linear
1905mm
PB 72 GSB2/GSR2 Aust.
35
20"
508mm