Troubleshooting M120 Fpcs And Cfpcs - Juniper M120 Hardware Manual

Multiservice edge router
Hide thumbs Also See for M120:
Table of Contents

Advertisement

Troubleshooting M120 FPCs and CFPCs

Problem
Solution
Related
Documentation
Copyright © 2018, Juniper Networks, Inc.
Description: The FPCs or CFPCs are not functioning normally.
As soon as an FPC (or CFPC) is seated in an operating router, the Routing Engine
downloads the FPC software to it under two conditions: the FPC is present when the
Routing Engine boots the Junos OS, and the FPC is installed and requested online through
the CLI or push button on the front panel. The FPC then runs diagnostics and enables
the PICs housed on it. During this time, the green LED labeled
the craft interface blinks. When the FPC is online and functioning normally, the
LED lights steadily.
To troubleshoot the FPCs:
Make sure the FPC is properly seated in the midplane. Check that each ejector handle
has been turned clockwise and is tight.
Issue the
show chassis fpc
in the sample output, the value
FPC is functioning normally:
user@host> show chassis fpc
Temp
Slot State
0
Empty
1
Empty
2
Online
3
Online
4
Online
5
Online
For more detailed output, add the
a slot number (
), which is optional:
2
user@host> show chassis fpc detail 2
State
Temperature
Total CPU DRAM
Start time
Uptime
For further description of the output from the commands, see the
M120 Flexible PIC Concentrators (FPCs) Description on page 51
M120 Compact FPCs (CFPCs) Description on page 54
Maintaining M120 FPCs and CFPCs on page 270
Replacing an M120 FPC on page 213
Replacing an M120 CFPC on page 219
command to check the status of installed FPCs. As shown
in the column labeled
Online
CPU Utilization (%)
(C)
Total
Interrupt
39
1
0
41
0
0
43
0
0
39
0
0
detail
option. The following example also specifies
Online
39 degrees C / 102 degrees F
128 MB
2006-05-02 08:53:29 PDT
1 hour, 51 minutes, 57 seconds
Chapter 32: Troubleshooting Components
above the FPC on
STATUS
indicates that the
State
Memory
Utilization (%)
DRAM (MB) Heap
Buffer
128
1
128
1
128
1
128
3
CLI Explorer
STATUS
59
59
58
59
.
287

Advertisement