CAUTION
Refrigerant and refrigerant oil
Be sure to only charge the unit with refrigerant HFC 134a.
Never attempt to use any other refrigerant (CFC12, HCF22, etc) with the
refrigeration unit.
If any other refrigerant not specified is charged, it may cause problems with the unit.
Use only Daikin specified oil (IDEMITSU, Daphne Hermetic Oil FVC46D) when
replacing the refrigerant oil.
If any other refrigerating machine oil not specified is charged, it may cause problems
with the unit.
DAPHNE
HERMETIC OIL
FVC46D
Open the oil can, just before charging the oil, and use all the oil in the can once
opened.
Do not leave the can open for 5 hours or longer to avoid moisture entry.
Using any refrigerant oil which has absorbed moisture may cause problems with the
unit.
Use only exclusive tools for HFC134a. (gauge manifold, charging cylinder, etc)
Do not use any tools for CFC12 or HCFC22.
Service ports with exclusive quick joints for HFC134a are provided in the refrigeration
unit to avoid improper refrigerant or refrigerant oil from entering into the refrigeration
circuit. (Refer to section 4.4.2)
The charging hose and gauge port are not interchangeable with those of previous
models using other refrigerants.
SUNISO
3GS-DI
Moisture
Moisture
7
7
OIL