Daikin LXE10E-A14 Service Manual page 36

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
No.
Function division
5
Self-diagnosis and
automatic back-up
6
Manual inspection
7
Automatic PTI
8
Data logging
9
Data retrieving
(Data output)
10
Communication
11
Power back-up
12
Chartless
13
G-SET mode
14
Data scroll
15
Data input
16
Automatic
Pump down
• Open-phase running
• Over current running
• CPU and peripheral device (electronic controller)
• Compressor running hour indication
• Evaporator fan individual operation (high speed)
• Evaporator fan individual operation (low speed)
• Condenser fan individual operation
• Indication of elapsed time since trip start/time resetting
• Evaporator fan run-hour indication
• Condenser fan run-hour indication
• Controller software version indication
• Temperature sensor calibration
• Elapsed days since last PTI.
• [PC] --- Pulp temperature sensor/cargo temperature sensor calibration
• [PC] --- Header information set of data logger
• [PC] --- All sensor data indication
• [PC] --- Controller built-in relay output display/MV output
(opening rate) indication/EV output (opening rate) indication
• Automatic PTI (SHORT) = Operation check of components
• Automatic PTI (FULL)
• Compressor total running hour
• Evaporator fan motor total running hour
• Condenser fan motor total running hour
• Trip data
• Pulp temperature data
• Cargo temperature data
• Alarm logging data
• Automatic PTI data
• Event data
• [PC] --- Alarm data
• [PC] --- Trip data
• [PC] --- Automatic PTI data
• [PC] --- Pulp temperature data
• [PC] --- Cargo temperature data
• [PC] --- Event data
• Remote monitoring
• Remote control
※Even while the power is off, the following works are possible.
• Setting, Temperature setting
Humidity setting
Defrosting interval setting
[PC] --- Container ID data setting
• Saving the logger data record
• Data retrieving (down loading)
• Alarm indication function (H code)
• Operation history indication function (D code)
• Pull-down time indication function (P code)
• Temperature logging data indication on LCD in simple graphic chart
※To be used when power supply capacity is small.
• Energy saving operation
• Temperature log scroll indication function
• Alarm log indication function
※The following works are possible using the indication panel
• Container ID (No.) entering
• Controller time setting
• Refelgerant is collected into the receiver and condensor coil.
3-2
Function
DECOS3b











Optional









Optional
Optional






Optional
Optional

Optional
Optional