Daikin LXE10E-A14 Service Manual page 53

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
6. SENSOR INDICATION MODE (continued)
CURRENT
SENSOR-2
(CT2)
AMBIENT
TEMPERATURE
SENSOR
(AMBS)
EVAPORATOR INLET
TEMPERATURE SENSOR
(EIS)
EVAPORATOR OUTLET
TEMPERATURE SENSOR
(EOS)
DISCHARGE GAS
TEMPERATURE SENSOR
(DCHS)
SUCTION
GAS SENSOR
(SGS)
SUCTION MODULATING
VALVE OPENING
(SMV)
ELECTRONIC
EXPANSION VALVE
(EV)
SUPPLY AIR
TEMPERATURE SENSOR
(SS)
RETURN AIR
TEMPERATURE SENSOR
(RS)
LED: The control temperature is displayed.
LCD: The compressor running current is displayed.
The display reads: " CT A".
(In Ampere.)
LED: The control temperature is displayed.
LCD: The ambient temperature is displayed.
The display reads: "Ab C".
(In ˚C or ˚F.)
LED: The control temperature is displayed.
LCD: The evaporator inlet temperature is displayed.
The display reads: "EI C".
(In ˚C or ˚F.)
LED: The control temperature is displayed.
LCD: The evaporator outlet temperature is displayed.
The display reads: "EO C".
(In ˚C or ˚F.)
LED: The control temperature is displayed.
LCD: The discharge gas temperature is displayed.
The display reads: "dC C".
(In ˚C or ˚F.)
LED: The control temperature is displayed.
LCD: The suction gas temperature is displayed.
The display reads: "SG C".
(In ˚C or ˚F.)
LED: The control opening is displayed.
LCD: The suction modulating valve opening is displayed.
The display reads: "SMV ".
(In % : 0 to 100%)
LED: The control opening is displayed.
LCD: The electronic expansion valve opening is displayed.
The display reads: "EV ".
(In % : 0 to 100%)
(During PTI only)
LED: The PTI selection and the step No. are displayed.
LCD: The supply air temperature is displayed.
The display reads: "SS C".
(In ˚C or ˚F.)
(During PTI only)
LED: The PTI selection and the step No. are displayed.
LCD: The return air temperature is displayed.
The display reads: "RS C".
(In ˚C or ˚F.)
3-19
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lxe10e-a15

Table of Contents