Daikin LXE10E-A14 Service Manual page 137

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
Alarm code
Content
E407
Evaporator inlet sensor (EIS)
malfunction
E409
Evaporator outlet sensor
(EOS) malfunction
E411
Ambient sensor (AMBS)
malfunction
E413
Low pressure transducer
(LPT) malfunction
E415
High pressure transducer
(HPT) malfunction
E417
Voltage sensor (PT1)
malfunction
E419
Voltage sensor (PT2)
malfunction
E421
Current sensor (CT1)
malfunction
E423
Current sensor (CT2)
malfunction
E425
Pulp temperature sensor
E427
(USDA1 to 3) malfunction
E429
E431
Humidity sensor (HuS)
malfunction
E603
Line breakage of suction
modulating valve (SMV) or
drive circuit malfunction or
wrong setting of controller
E607
Abnormal contact point of
manual defrost key
(sheet key)
E707
Momentally power failure
Line breakage
Short circuit
Wrong wiring
CPU board malfunction
Line breakage
Short circuit
Wrong wiring
CPU board malfunction
Line breakage
Short circuit
Wrong wiring
CPU board malfunction
Line breakage
Short circuit
Wrong wiring
CPU board malfunction
Line breakage
Short circuit
Wrong wiring
CPU board malfunction
Sensor malfunction
CPU board malfunction
Sensor malfunction
CPU board malfunction
Sensor malfunction
CPU board malfunction
Sensor malfunction
CPU board malfunction
Wrong wiring in the USDA receptacle.
Line breakage in the USDA receptacle.
Short circuit in the USDA receptacle.
Junction cable breakage
Junction cable poor contact
Wrong wiring in the control box
Short circuit in the control box
Pulp temperature sensor malfunction
CPU board malfunction
Lead wire breakage
Wrong wiring
Humidity sensor malfunction
CPU board malfunction
Lead wire breakage
Wrong wiring
CPU board malfunction
Wrong setting of initial setting of controller (DECOS a, b, c)
Switch malfunction
Short circuit
CPU board malfunction
Commercial power supply stops for 40 to 300msec.
6-7
Possible cause

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lxe10e-a15

Table of Contents