Temperature record scroll function
The control sensor value record for the last 7 days is displayed in sequence (scroll) beginning with the
latest one and ending with oldest one, so that easy inspection of the previous operation data is enabled
on board.
<Operation procedure>
The LED indicates the control temperature, and the LCD displays the data or time and the non-control
temperature in turn. (In the partial frozen and frozen modes, return air temperature is the controlled
temperature, and in the chilled mode, supply air temperature is the controlled temperature.)
To pauze the scrolling action, press the
press the
or
key again. If arrow key is not pressed for 10 seconds, the continuous scrolling
action is resumed. To see data from the beginning, press and hold the
To restore the current indication mode screen, press the
If key operation is not performed for 5 minutes, the current indication mode screen is resumed.
If the successive (scroll) screen is currently displayed, the current indication mode screen is resumed
when 5 minutes elapses after indication ends.
To return to the operation setting mode, press the
CAUTION
or
key. To advance to the next temperature record,
key.
key.
S
The displayed temperature is not the current
instantaneous value but an average taken in a
specific logging interval.
Therefore, the printed control temperature on the
trip report (instantaneous value) printed with the aid
of personal computer may differ from the sensor
data of the chartless function.
This is not an error.
3-22
key for 3 seconds.