Daikin LXE10E-A14 Service Manual page 120

Marine type container refrigeration unit
Table of Contents

Advertisement

https://daikin-p.ru
GCaution on the service work
qBe sure not to bend the refrigerant pipe
when pushing the quick joint during
connection work.
wIf the installation fails due to movement of
the sleeve, try it again after returning the
sleeve to the original position.
eThe remaining pressure in the charge hose
may cause installation failure. In this case,
try it again after relieving the pressure in
the hose.
Fusible plug
Service port (High pressure)
Low-pressure side hose
Quick joint
(Low pressure)
Compound gauge
Service port (Low pressure)
Liquid receiver
Pressure
gauge
4-17
Hose for air purge
and refrigerant charge
Structure of gauge manifold
Open state
Open and closed states of gauge manifold
(2) Removal of gauge manifold
Holding the quick joint at A , pull the section
B (sleeve) upward and remove the quick
joint from the service port.
Sleeve
Click
CAUTION
Be sure to attach the cap to the
service port after the removal of the
manifold.
Gauge manifold
Passage open-
/closing cock
High-pressure
side hose
Quick joint
(high pressure)
Closed state

Advertisement