KTM 250 EXC TPI 2019 Repair Manual page 100

Hide thumbs Also See for 250 EXC TPI 2019:
Table of Contents

Advertisement

9 SHOCK ABSORBER, SWINGARM
98
When the pressure gauge reaches the specified value, turn
control lever Oil reservoir
Guideline
0 bar
The vacuum gauge drops to the required value.
8 mbar
200270-10
When the vacuum gauge reaches the required value, turn con-
trol lever Oil reservoir
Guideline
8 mbar
The pressure gauge drops to the required value.
0 bar
200267-10
When the pressure gauge reaches the specified value, turn
control lever Damper
Guideline
0 bar
Oil is pumped into the damper.
The pressure gauge increases to the required value.
3 bar
200268-10
When the pressure gauge reaches the specified value, turn
control lever Damper
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
When the pressure gauge reaches the required value, activate
the On/Off switch.
200269-10
Guideline
0 bar
The vacuum pump is switched off.
B
Slide O-ring
value (distance
Guideline
5 mm
Depth micrometer (T107S) (
Slide the floating piston into the reservoir to the shortened
position using the special tool.
B04502-10
5
to Vacuum.
5
to Equalize Pressure.
4
to Pressure.
4
to Vacuum.
to the end of the special tool by the specified
A
minus specified value).
p. 372)