DME Manager Error Messages

If DME Manager displays an error message, look for the solution in the following table.
Message
Cannot compile because
configuration contains no
components!
Cannot display more than
32 meters!
COM port open error 5
Component position
error!
Configuration must be
compiled before saving!
Configuration must be
compiled before sending!
DME32 and DME Manager
configurations do not
match!
DME32 not found!
Error reading file!
Error receiving
configuration!
Error sending
configuration!
Error writing file!
Grid spacing is too large
or too small!
Incorrect password!
No configuration selected!
"NO DATA" is an invalid
file name!
Not a DME file!
Printer setup error!
Reason
An attempt was made to compile a con-
figuration that contains no compo-
nents.
An attempt was made to display more
than 32 meters.
The COM port is in use by another
device.
An error occurred while trying to dis-
play the configuration.
An attempt was made to save a config-
uration that has not been compiled.
An attempt was made to send an
uncompiled configuration to the
DME32.
The DME Manager and DME32 config-
uration data does not match.
The DME32 was not detected when
DME Manager was started.
An error occurred while trying to open
a file. Perhaps the file is already in use,
or has not yet been saved.
An error occurred while receiving a con-
figuration from the DME32.
An error occurred while sending a con-
figuration to the DME32.
An error occurred while trying to write
to a file. Perhaps it's in use, or is write
protected.
The specified grid spacing is too large
or too small.
The password entered was incorrect.
An attempt was made to send a config-
uration, but no configuration was
selected.
"NO DATA" cannot be used as a file
name.
An attempt was made to open a file
other than a DME file.
An error occurred while trying to read
the printer setup information. Perhaps
the printer is not set up correctly, or a
suitable driver is not available.
DME Manager Error Messages
Solution
Add some components, and then try
compiling again.
A maximum of 32 meters can be dis-
played simultaneously.
Disable the device using the COM port.
Open the "setup.ini" file in the DME
folder and make sure that the COM set-
ting is correct. If you are using com port
2, for example, the setting should be
"COM2".
Try opening the configuration again, or
try receiving it from the DME32 again.
Compile the configuration, and then try
saving again.
Compile the configuration, and then try
sending again.
Match the data, and then try sending
the configuration again.
Continue using only DME Manager, or
check the DME32 connection and
restart DME Manager.
Check if the file is already in use, or
check if it has been saved, and then try
opening again.
Check the DME32 connection, and then
try receiving again.
Check the DME32 connection, and then
try sending again.
Enter another file name, or turn off the
write protection, and then try saving
again.
Enter a grid spacing within the valid
range.
Enter the correct password.
Select a configuration, and then try
sending again.
Enter a file name other than "NO
DATA".
Open, and drag open only DME files
Set up the printer correctly.