If the DME32 displays an error message, look for the solution in the following table.
Message
****** WARNING ******
LOW BATTERY
ABORTED-TooMany
Errors!
Application Prog Error!
CASCADE ERR (My ID: )
CPU Address Error!
DMA Address Error!
DME I/F ERR
Ext RAM Read/Write err!
Flash ROM checksum err!
Flash ROM device err!
Flash ROM Write Error!
Flash ROM write error!
Illegal Instruction!
Illegal interrupt!
Illegal slot!
NMI Request!
TIME OUT ERR
Unexpected vector!
User Break!
DME32—Owner's Manual
Reason
The internal battery has expired.
Several errors occurred while trying to
download the firmware.
The application program is not regis-
tered in the flash ROM.
When the DME32 is turned on, it
checks its ID number. If this number
does not match, a connection error
occurs.
An SH2 error trap occurred.
Communication failed between
DME32s in a multiple-unit system. Per-
haps a cascade cable has been discon-
nected, or a DME32 is not turned on.
An error occurred while reading or writ-
ing to the external RAM.
A flash ROM write error occurred.
A manufacture or device code error
occurred.
An SH2 error trap occurred.
A flash ROM erase error occurred.
An SH2 error trap occurred.
When a multiple-unit DME32 system is
turned on, DME32s with a cable con-
nected to their CASCADE IN wait for
connection confirmation from the next
DME32. If this confirmation is not
received within 10 seconds, a time out
error occurs.
An SH2 error trap occurred.
Solution
Save the configurations to DME Man-
ager or a PC Card, and then ask your
Yamaha dealer to replace the battery.
Try downloading again.
Register the application program in the
flash ROM.
Make sure the cascade cables are con-
nected in the proper order.
Check the cascade cables, and make
sure all DME32s are turned on.
Ensure that cascaded DME32s are
turned on within 10 seconds of each
other. Make sure that all DME32s are
turned on. Make sure the cascade cables
are connected properly.