Using Password Protection

The Protection function is for use mainly in Run mode, when DME Designer is used to
control the DME32, and can be used to restrict component parameter editing or to pre-
vent any operation whatsoever. Three levels of protection are available: full access, lim-
ited access, and no access. Note that this protection function has nothing to do with the
DME32's front panel Protect function.
Passwords can be assigned to the Off and Component modes, preventing unauthorized
mode changes. Operation mode does not have its own password, although you'd need
to know either the Off or Component password in order to switch from Operation
mode. Passwords can be up to 16 characters long.
The current protection setting is shown in the protection section of the status bar. See
"Status bar" on page 25 for more information.
The three protection modes are explained below.
Off —This mode offers full access to all functions. If the Off password has been set, it
must be entered in order to switch to Off mode from either Component or Operation
mode.
Component —This mode offers limited access. Components whose Protect option is
checked (see page 80) cannot be edited. Other components can be edited and scenes
can be stored or recalled as normal. If the Component password has been set, it must
be entered in order to switch to Component mode from either Off or Operation mode.
Operation —This mode offers no access. Component parameters cannot be edited,
scenes cannot be stored or recalled, and configurations cannot be recalled. If the Off or
Component password has been set, the correct password must be entered in order to
switch from Operation mode to that mode.
The following table shows exactly what can and cannot be done in each mode.
Recall configurations
Recall scenes
Edit component parameters
Edit configurations
Save configurations
Save configurations under a new name
Open new configuration windows
Open saved configurations
Send configurations to the DME32
Receive configurations from the DME32
Change mode (Edit, Cable, Run)
Print
Close configurations
Zoom configuration windows
Quit DME Manager

Using Password Protection

Operation
Component
No
No
Components whose
Protect option is on
No
cannot be edited.
Other components
can be edited.
No
Yes
Yes
No
No
No
No
Yes
No
Yes
No
Yes
DME32—Owner's Manual
83
No
Yes
No
Yes
Yes
No
No
No
No
Yes
No
Yes
No
Yes