7-7. HIGH STATIC PRESSURE DUCT TYPE

„ MODEL : ARUH36TLAV
Outdoor
temperature
68°FDB / 59 °FWB
(°FDB)
TC
SHC
50
22.8
18.1
59
22.8
18.1
70
22.8
18.1
73
22.8
18.1
77
22.8
18.1
81
22.8
18.1
86
22.8
18.1
91
22.8
18.1
95
22.8
18.1
99
22.8
18.1
104
22.8
18.1
109
22.8
18.1
115
22.8
18.1
„ MODEL : ARUH48TLAV
Outdoor
temperature
68°FDB / 59 °FWB
(°FDB)
TC
SHC
50
30.4
24.2
59
30.4
24.2
70
30.4
24.2
73
30.4
24.2
77
30.4
24.2
81
30.4
24.2
86
30.4
24.2
91
30.4
24.2
95
30.4
24.2
99
30.4
24.2
104
30.4
24.2
109
30.4
24.2
115
30.4
24.2
„ MODEL : ARUH60TLAV
Outdoor
temperature
68°FDB / 59 °FWB
(°FDB)
TC
SHC
50
38.1
31.6
59
38.1
31.6
70
38.1
31.6
73
38.1
31.6
77
38.1
31.6
81
38.1
31.6
86
38.1
31.6
91
38.1
31.6
95
38.1
31.6
99
38.1
31.6
104
38.1
31.6
109
38.1
31.6
115
38.1
31.6
TC : Total Capacity kBtu/h.
SHC : Sensible Heat Capacity kBtu/h.
73°FDB / 61 °FWB
75°FDB / 63 °FWB
79°FDB / 64 °FWB
TC
SHC
TC
SHC
TC
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
26.1
22.0
29.4
22.9
31.1
73°FDB / 61 °FWB
75°FDB / 63 °FWB
79°FDB / 64 °FWB
TC
SHC
TC
SHC
TC
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
34.8
29.4
39.2
30.6
41.4
73°FDB / 61 °FWB
75°FDB / 63 °FWB
79°FDB / 64 °FWB
TC
SHC
TC
SHC
TC
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
43.5
38.6
49.0
40.0
51.8
- (02 - 39) -
COOLING CAPACITY
in kBtu/h
Indoor temperature
80°FDB / 67 °FWB
82°FDB / 68 °FWB
SHC
TC
SHC
TC
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
37.7
26.2
36.0
25.5
36.9
26.2
35.4
25.2
35.8
Indoor temperature
80°FDB / 67 °FWB
82°FDB / 68 °FWB
SHC
TC
SHC
TC
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
50.2
35.0
48.0
33.9
49.2
35.0
47.2
33.6
47.7
Indoor temperature
80°FDB / 67 °FWB
82°FDB / 68 °FWB
SHC
TC
SHC
TC
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
62.8
46.0
60.0
44.3
61.5
46.0
59.0
43.9
59.6
86°FDB / 72 °FWB
90°FDB / 73 °FWB
SHC
TC
SHC
TC
SHC
26.7
44.2
27.9
45.9
30.9
26.7
44.2
27.9
45.9
30.9
26.7
44.2
27.9
45.9
30.9
26.7
44.2
27.9
45.7
30.9
26.7
44.2
27.9
44.9
30.6
26.7
43.8
27.7
44.2
30.3
26.7
42.8
27.4
43.3
30.0
26.7
41.9
27.0
42.4
29.6
26.7
41.2
26.7
41.6
29.3
26.7
40.4
26.5
40.9
29.1
26.7
39.5
26.1
39.9
28.7
26.4
38.5
25.8
38.9
28.4
26.0
37.4
25.3
37.8
28.0
86°FDB / 72 °FWB
90°FDB / 73 °FWB
SHC
TC
SHC
TC
SHC
35.7
59.0
37.2
61.2
41.3
35.7
59.0
37.2
61.2
41.3
35.7
59.0
37.2
61.2
41.3
35.7
59.0
37.2
60.9
41.1
35.7
59.0
37.2
59.9
40.8
35.7
58.4
36.9
58.9
40.4
35.7
57.1
36.5
57.7
39.9
35.7
55.9
36.0
56.5
39.5
35.7
54.9
35.6
55.5
39.1
35.7
53.9
35.3
54.5
38.8
35.7
52.6
34.8
53.2
38.3
35.2
51.4
34.3
51.9
37.8
34.6
49.8
33.8
50.4
37.3
86°FDB / 72 °FWB
90°FDB / 73 °FWB
SHC
TC
SHC
TC
SHC
46.6
73.7
48.4
76.5
53.9
46.6
73.7
48.4
76.5
53.9
46.6
73.7
48.4
76.5
53.9
46.6
73.7
48.4
76.1
53.8
46.6
73.7
48.4
74.9
53.3
46.6
72.9
48.1
73.7
52.9
46.6
71.4
47.5
72.1
52.3
46.6
69.9
47.0
70.6
51.8
46.6
68.6
46.5
69.3
51.3
46.6
67.4
46.1
68.1
50.9
46.6
65.8
45.5
66.5
50.4
46.1
64.2
44.9
64.9
49.8
45.3
62.3
44.2
62.9
49.1