z SET3-1: Two-stage setting
Cooling setting temperature
SW
SET3-2
OFF
u
ON
Heating setting temperature
SW
SET3-3
OFF
u
OFF
ON
ON
NOTES:
● Setting values are the limit temperature for cooling and heating.
● Energy saving performance is improved in the order from Cooling Pattern 1 to 2 and Heating pattern 1 to 4.
„ Delay OFF setting (SET2)
Delay OFF is the function to operate continuously even after reaching to the set temperature of
thermostat. This function may make air conditioning efficient.
Set the Delay OFF time by SW SET2-3 and SW SET2-4.
SW
SET2-3
OFF
u
OFF
ON
ON
„ Fun setting (Signal on terminal G) (SET2)
SW
SET2-1
OFF
u
OFF
ON
ON
Cooling stage 1 setting
Temperature °F (°C)
68 (20)
72 (22)
SW
Cooling stage 1 setting
SET3-4
Temperature °F (°C)
OFF
81 (27)
ON
77 (25)
OFF
75 (24)
ON
70 (21)
SW
SET2-4
OFF
ON
OFF
ON
SW
SET2-2
OFF
ON
OFF
ON
- (07 - 141) -
(u...Factory setting)
Cooling stage 2 setting
Temperature °F (°C)
64 (18)
68 (20)
Cooling stage 2 setting
Temperature °F (°C)
86 (30)
82 (28)
79 (26)
75 (24)
(u...Factory setting)
Delay off time
0 minute
5 minutes
10 minutes
20 minutes
(u...Factory setting)
Indoor unit airflow
AUTO
HIGH
MED
LOW
Remarks
Pattern 1
Pattern 2
(u...Factory setting)
Remarks
Pattern 1
Pattern 2
Pattern 3
Pattern 4