Fujitsu AIRSTAGE AUUA7TLAV Operating Manual
Hide thumbs Also See for AIRSTAGE AUUA7TLAV:

Advertisement

Quick Links

AUUA4TLAV1
AUUA7TLAV
AUUA9TLAV
AUUA12TLAV
AUUA14TLAV
AUUA18TLAV
AUUA24TLAV
AUUB18TLAV
AUUB24TLAV
AUUB30TLAV
AUUB36TLAV
OPERATING MANUAL
INDOOR UNIT (Cassette type)
Keep this manual for future reference.
MODE D'EMPLOI
UNITÉ INTÉRIEURE (Type cassette)
Conservez ce manuel pour pour toute référence ultérieure.
MANUAL DE FUNCIONAMIENTO
UNIDAD INTERIOR (Tipo casete)
Conserve este manual para posibles consultas futuras.
PART No. 9369313271-02

Advertisement

loading

Summary of Contents for Fujitsu AIRSTAGE AUUA7TLAV

  • Page 1 OPERATING MANUAL INDOOR UNIT (Cassette type) Keep this manual for future reference. MODE D’EMPLOI UNITÉ INTÉRIEURE (Type cassette) Conservez ce manuel pour pour toute référence ultérieure. MANUAL DE FUNCIONAMIENTO AUUA4TLAV1 AUUA7TLAV UNIDAD INTERIOR (Tipo casete) Conserve este manual para posibles consultas futuras. AUUA9TLAV AUUA12TLAV AUUA14TLAV...
  • Page 2: Table Of Contents

    OPERATING MANUAL ● This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of ex- PART No. 9369313271-02 perience and knowledge, unless they have been given supervision or VRF system indoor unit (Cassette type) instruction concerning use of the appliance by a person responsible for their safety.
  • Page 3: Manual Auto Operation

    MANUAL AUTO OPERATION OPERATING TIPS Use the MANUAL AUTO operation in the event the remote control unit is Operation and Performance lost or otherwise unavailable. About priority state and standby state CAUTION ● Multiple indoor units can be connected within the same system. De- pending on the system, choice of operating mode are limited.
  • Page 4: Cleaning And Care

    ● If the air conditioner is operated under higher temperature conditions 5. Close the intake grille and push the intake grille’s than those listed, the built-in protection circuit may operate to prevent hooks outward. internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other Air Filter...
  • Page 5: Troubleshooting

    Smells: Cleaning the body ● Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken Wash the body with warm water, and then dry with a clean and soft cloth. into the air conditioner.
  • Page 6: Specifications

    SPECIFICATIONS AUUA AUUA AUUA AUUA AUUA AUUA AUUA MODEL TLAV1 TLAV TLAV TLAV TLAV TLAV TLAV POWER SOURCE 208/230 V ~ 60 Hz AVAILABLE 187 to 253 V VOLTAGE RANGE COOLING [Btu/h 4,000 7,500 9,500 12,000 14,000 18,000 24,000 CAPACITY (kW)] (1.2) (2.2)