„ INSTALLATION PLACE
11 in. (256 mm) or more (AUUB18,24,30)
12 in. (298 mm) or more (AUUB36,48)
119 in. (3,000 mm) or more
71 in. (1,800 mm) to H
40 in. (1,000 mm) or more
Model name
Standard mode
High Ceiling mode
4 direction
NOTE: Use the "Insulation kit for high humidity" (option), when the condition under the roof
is over 80% in humidity and over 30°C in temperature. Otherwise, there is a risk of
condensation on the ceiling.
Strong and durable ceiling
Obstruction
Floor
H (The maximum height from floor to ceiling) in. (mm)
3 direction
4 in. (100 mm) or more *1
- (04-29) -
60 in.
(1,500 mm )
or more
AUUB36/48
126 (3,200)
166 (4,200)
*1: Ensure sufficient
service access during
installation.