Parameter
Description
Outdoor
Temperature
Options are off, Internet (AccuWeather) or sensor. Default is Internet (AccuWeather).
Source
Proximity Control
Options are ON and OFF. Default is OFF. Is used to wake-up the display from screen saver mode when motion near the HD Display is detected.
Reset thermostat
Resets the thermostat settings to factory default.
Screen Locked
Options are unlocked, partially locked and locked. Default is unlocked.
Screen Saver
Options are off, weather, power save and logo. Default is off.
Options are ON and OFF. Default is OFF. This allows a wider low and high temperature. Normal range is 60 to 90°F (15.5 to 32.0°C). When this parameter is set to ON,
Wide Setpoint
the range is 40 to 100°F (0.0 to 40°C). This feature can also be set through the user interface setting screen. From the home screen go to menu > settings > heat &
cool > wider set-point range.
Table 11. Utilities
Parameter
Description
Restart smart hub
Restarts the smart hub.
Re-configure
Re-configure HVAC system.
System
Reset HVAC
Resets all HVAC equipment.
Equipment
Factory Reset
Resets thermostat to factory default settings.
Thermostat
Factory Reset
Resets smart hub parameters back to factory default.
Smart Hub

Tests

Verify Airflow Per Zone is the first screen to appear under this selection. If
no zoning is installed, zone airflow settings will be for zone 1 only. If zoning
equipment is detected by the system then zones 1 through 4 will be listed.
These screens allow for verification and modification of CFMs for blower,
heating and cooling circulation. Touch continue to proceed to the next screen.
Select Test Mode is the next screen to appear. Your options are automated
tests or manual tests. Select the desired option and select apply.
• Automated Tests: Select this options and the next screen will allow you to
select the specific tests available for your hardware configuration. The test
are automatic and no installer / service technician's attendance is required.
When the automatic testing is complete the system returns to the consumer
home screen. A updated installation report is generated and available in
Lennox Pros under the Homeowners account.
Table 10. Thermostat (HD Display) Parameters
• Manual Test: Depending on hardware present, various tests are available.
By default all items to be tested are enabled. Selecting a specific test will un-
check the item. When a specific set of tests are completed the results will be
displayed on the screen next to the tested item. Touch continue to proceed to
the next set of test items. Once all tests are completed press done to return
to the touch tests to run screen. Touch the left arrow at the top left side of
screen to return to the Dealer Control Center