11 - 12
1.
Make sure the jumper in the PGD(2)-U10 ADP for the associated Door
Box is set correctly. (Refer to Figure 11-4
on page 11-4).
Settings
2.
If a line cord was not previously connected to the PGD(2)-U10 ADP,
complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD(2)-U10 ADP. For each module, run
one-pair 24 AWG station cable from the cross-connect block to a
modular jack. Ground the unused pair.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1 connector on the
PGD(2)-U10 ADP.
7.
If wall mounting the Door Box, remove the screw on the front of the Door
Box.
8.
Remove the back half of the Door Box and attach this mounting bracket
to the wall with the two screws provided.
9.
Connect the two-conductor station cable from the CN4 connectors within
the PGD(2)-U10 ADP to the Door Box terminals. These wires must be
routed through the opening in the bottom of the Door Box mounting
bracket.
Be sure to maintain the proper polarity.
10.
Replace the front half of the Door Box and reattach the screw to secure it
in place.
11.
To connect a Door Box to an external relay for an unlock device, for
example, connect one-pair 24 AWG station cable from the Relay 5 (for
Door Box 1) or Relay 6 (for Door Box 2) connectors (CN5) in the
PGD(2)-U10 ADP. Connect the opposite end to the unlock device.
Refer to External Page and Door Box/Page Relays on page 11-18 for additional
information when using the CD-CP00-US relay.