Table 6-5 Cd-Cp00-Us Switch Settings; Table 6-6 Cd-Cp00-Us Switch 6 Settings - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
SW6-1
SW6-2
SW6-3
6 - 20
3.1.3
Switch Settings
Refer to

Table 6-5 CD-CP00-US Switch Settings

system reset and with system power on.
Blade Layout on page 6-14
the CD-CP00-US blade.
Table 6-5 CD-CP00-US Switch Settings
USB Memory Status
With a system restart or a system reset while holding the SW1
switch:
When USB Memory is not
installed:
Switch
SW1 - Load
When USB Memory is
Switch
installed:
When an unauthorized USB
device is installed:
With the system power on, pressing the SW1 switch:
When USB Memory is not
installed:
Switch
SW1 - Load
When USB Memory is
Switch
installed:
When an unauthorized USB
is installed:

Table 6-6 CD-CP00-US Switch 6 Settings

Configuration
OFF
ON
OFF
Customer information is stored in the RAM memory and, in
case of a power failure, will be restored. The lithium battery in
the system saves the RAM memory when power is lost.
shows the location of the SW1 switch on
Not Used
Test Mode
RS232C Select
Installing the SV8100/SV8300 Blades
UNIVERGE SV8100/SV8300
for system restart/
Figure 6-3 CD-CP00-US
Operation
Cold Start occurs.
USB Memory contents loaded.
System does not start and an "Illegal
USB device is connected" alarm is
recorded.
No operation.
USB Memory contents loaded.
No operation.
Note
ON = Test Mode
OFF = Normal