3
SPECIFICATIONS
3.4.10

Offset/gain setting mode (Un\G26, Un\G27)

(1) Select a channel for adjusting the offset/gain setting in the offset/gain
setting mode.
(2) Select a channel for adjusting the offset value in Un\G26, and a channel
for adjusting the gain value in Un\G27.
(3) Setting multiple channels at the same time is possible; however, set
offset and gain separately (select "0" in either Un\G26 or Un\G27). When
both "offset" and "gain" are set at the same time, an error (error code
500) occurs.
(4) For details of the offset/gain setting, refer to Section 4.6.
Un\G26
(Offset specification)
Un\G27
(Gain specification)
b15 b14 b13 b12 b11
b10
0
0
0
0
0
0
0
0
0
0
0
0
Data for b8 to b15 are fixed to "0".
3.4.10 Offset/gain setting mode (Un\G26, Un\G27)
b9
b8
b7
b6
b5
b4
0
0
CH8 CH7 CH6 CH5
0
0
CH8 CH7 CH6 CH5
3.4 Buffer Memory
b3
b2
b1
b0
CH4 CH3 CH2 CH1
CH4 CH3 CH2 CH1
1: Setting channel
0: disable
3
- 36
1
2
3
4
5
6
7
8