NEC NEAX 2000 IPS Maintenance Manual page 95

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

B
CMF6
Assign specification of particular data to out-
put.
NOTE:
When setting this data, only the command of YY is output by XXXth byte of MP-FP com-
mand.
Assign Station number or Trunk number to
output Status Output.
END
• To display whether command data is stored, and to clear the stored data in command buffer, do the
following programming.
START
CMF6
Assign displaying the stored data in command
buffer and clearance of the stored data in com-
mand buffer.
END
DESCRIPTION
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Y=2
(1)
30: Specification of particular data for
command code of CMF6 Y=2>00
31: Specification of particular data for
command code of CMF6 Y=2>10
32: Specification of particular data for
command code of CMF6 Y=2>11
33: Specification of particular data for
command code of CMF6 Y=2>12
(2)
XXXZZ
XXX
ZZ
NONE : No data
Y=2
(1)
40: Status Output
(2)
X-XXXXXXXX: Station No.
DXXX : Trunk No.
NONE : No data
Y=2
(1)
99: Displaying the stored data in command
buffer and clearance of the stored data
in command buffer
(2)
0
: No stored data
1
: Stored data remain
CCC: Clear the buffer
– 85 –
ONLINE MP-FP COMMAND OUTPUT
DATA
: 000-254: Byte location of com-
mand data
: 00-FF: Byte data
XXX: 000-255
DATA
NWA-008847-001 Rev.3.0
a6ch1001.fm
JULY/01/2006