FAULT
KIND
FAULT CONTENT
NUMBER
08
FP/AP card down
09
Power failure
Remedial Action on Each Fault Kind
FAULT INFORMATION
3:
XX XX XX XX
FP/AP Number
[Series 3200 R6.1 or before]
C0-C3 : FP No. 00-03
D0-D3: FP No. 16-19
C4-CF: AP No. 04-15
D4-DF: AP No. 20-31
[Series 3200 R6.2]
C0-CF: FP No. 00-15
D0-DF: FP No. 16-31
C4-CF: AP No. 04-15
D4-DF: AP No. 20-31
[Series 3300 or later]
C0-CF: FP No. 00-15
D0-DF: FP No. 16-31
E0-EF : FP No. 32-47
F0-FF : FP No. 48-63
C4-CF: AP No. 04-15
D4-DF: AP No. 20-31
3:
XX XX XX XX
Power Failure Kind 00:AC input
Power Failure Kind 01: Fuse break
Power Failure Kind 02: PWR alarm
– 141 –
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
Power Failure Kind
(See below.)
failure
REMEDIAL ACTION
Replace the correspond-
ing FP or AP card indi-
cated in the FP/AP
Number.
Check to see if the AC
power source is cut off
or the plug is discon-
nected.
Check for a break in the
battery fuse.
Check the output
1
voltage of the PWR
card.
Replace the PWR
2
card.
Continued on next page