(7)
To read the status of upgraded side/outdated side of MP card, do the following programming (for
maintenance technician-use).
START
CM0C
For each Site, read the status of upgraded side/
outdated side of MP card.
NOTE1:
NOTE2:
END
DESCRIPTION
The current status of the upgraded
side/outdated side of MP card is dis-
played.
When the communication between
Main Site and Remote Site cannot
operate normally, "HARDWARE
ERROR" is displayed.
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Y=52
(1)
XX06
XX: 00: Main Site No.
01-30: Remote Site No.
(2)
XX XX ZZ ZZ
XX: 00/01: Side type
XX: 00/01: Side status
ZZ : 00/01: Side type
ZZ : 00/01: Side status
XX=0 side
ZZ=1 side
Side type : 00: Upgraded side
Side status : 00: Normal
– 77 –
MP PROGRAM DOWNLOAD (FTP)
DATA
01: Outdated side
01: Undefined