NEC NEAX 2000 IPS Maintenance Manual page 94

Internet protocol server
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

A
Assign the display of IN command/OUT com-
CMF6
mand.
Assign the displayed terminal
NOTE:
When using the communication software, set the second data to 0.
Assign whether to insert a line feed for each
command.
NOTE:
When executing command output in online mode (SW3 of MP card is set to 0), regardless
of second data setting, insert a line feed for each command.
Assign whether to add Minute/Second Indica-
tion to the header.
NOTE:
This command is effective when second data of CMF6 Y=2>06 is set to 0.
B
DESCRIPTION
CHAPTER 1 MAINTENANCE SERVICE FEATURES
Y=2
(1)
03: IN command/OUT command setting
(2)
0
: Display both IN command/OUT
command
1
: Display only OUT command
2
: Display only IN command
3
: Not displayed
CCC: Clear all the data of CMF6 Y=2
Y=2
(1)
04: Specification of displayed terminal
(2)
0 : Other than MATWorX
1 : MATWorX
Y=2
(1)
06: Whether to insert a line feed or not
(2)
0 : Inserted after each command
1 : Not inserted after each command
Y=2
(1)
07: Minute/Second Indication
(2)
0 : Add Minute/Second Indication to the
header
1 : Not add Minute/Second Indication to
the header
– 84 –
ONLINE MP-FP COMMAND OUTPUT
DATA
NWA-008847-001 Rev.3.0
a6ch1001.fm
JULY/01/2006

Advertisement