CARD NAME
PN-30PRTA
RUN lamp is not
(PRT)
flashing
LC lamp is not on ISDN Primary
PCM lamp is on
FRM lamp is on
MFRM lamp is on Multi-Frame
RMT lamp is on
MRMT lamp is on Multi-Frame
AIS lamp is on
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of PRT card
Rate D-channel
data link connec-
tion failure
No PCM signals
arrive from the
distant office
Frame Alignment
signals from the
distant office can
not be received
Alignment signals
from the distant
office cannot be
received
Frame Alignment
signals cannot be
sent to the remote
PBX
Alignment signals
cannot be sent to
the remote PBX
Remote PBX is in
local loopback
state
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the programming data:
1
CM05 Y=0/Y=1, CM07 Y=1.
Check to see if the SENSE switch is
2
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
3
(Down Up Down)
If the fault cannot be cleared,
4
replace the card.
Check the local office line or public net-
work line.
Check to see if the line is correctly
1
connected to the PRT card.
Plug and unplug the PRT card.
2
Repeat this two or three times.
Check the receive line and external
1
equipment.
Replace the remote PRT card.
2
Check the receive line and external
1
equipment.
Replace the remote PRT card.
2
Check the transmission line and
1
external equipment.
Replace the PRT card.
2
Confirm the switch setting on the
1
PRT card indicating an alarm.
Replace the PRT card not indicating
2
an alarm, with a spare.
Check the switch settings of the remote
PRT card.
– 194 –