CARD NAME
PN-4RSTB
RUN lamp is not
(MFR)
flashing
PN-4RSTC
RUN lamp is not
(CIR)
flashing
Remedial Action on Each Lamp Status
LAMP
FAULT
STATUS
CONTENT
Abnormal opera-
tion of MFR card
Abnormal opera-
tion of CIR card
CHAPTER 2 TROUBLESHOOTING
FAULT DIAGNOSIS AND TROUBLESHOOTING
REMEDIAL ACTION
Confirm the programming data:
1
CM05 Y=0.
Check to see if the SENS switch is
2
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
3
(Down Up Down)
If the fault cannot be cleared,
4
replace the card.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the SENSE switch is
2
set as per the AP Number (04-15)
assigned by CM05 Y=0.
Reset the MB switch.
3
(Down Up Down)
If the fault cannot be cleared,
4
replace the card.
– 195 –
Continued on next page
NWA-008847-001 Rev.3.0
a6ch2001.fm